1 |
The name for the custom resource object. |
2 |
The namespace where the SR-IOV Network Operator is installed. |
3 |
The resource name of the SR-IOV network device plugin. You can create multiple SR-IOV network node policies for a resource name.
When specifying a name, be sure to use the accepted syntax expression ^[a-zA-Z0-9_]+$ in the resourceName .
|
4 |
The node selector specifies the nodes to configure. Only SR-IOV network devices on the selected nodes are configured. The SR-IOV Container Network Interface (CNI) plugin and device plugin are deployed on selected nodes only.
|
The SR-IOV Network Operator applies node network configuration policies to nodes in sequence. Before applying node network configuration policies, the SR-IOV Network Operator checks if the machine config pool (MCP) for a node is in an unhealthy state such as Degraded or Updating . If a node is in an unhealthy MCP, the process of applying node network configuration policies to all targeted nodes in the cluster pauses until the MCP returns to a healthy state.
To avoid a node in an unhealthy MCP from blocking the application of node network configuration policies to other nodes, including nodes in other MCPs, you must create a separate node network configuration policy for each MCP.
|
|
5 |
Optional: The priority is an integer value between 0 and 99 . A smaller value receives higher priority. For example, a priority of 10 is a higher priority than 99 . The default value is 99 . |
6 |
Optional: The maximum transmission unit (MTU) of the virtual function. The maximum MTU value can vary for different network interface controller (NIC) models. |
7 |
Optional: Set needVhostNet to true to mount the /dev/vhost-net device in the pod. Use the mounted /dev/vhost-net device with Data Plane Development Kit (DPDK) to forward traffic to the kernel network stack. |
8 |
The number of the virtual functions (VF) to create for the SR-IOV physical network device. For an Intel network interface controller (NIC), the number of VFs cannot be larger than the total VFs supported by the device. For a Mellanox NIC, the number of VFs cannot be larger than 127 . |
9 |
The externallyManaged field indicates whether the SR-IOV Network Operator manages all, or only a subset of virtual functions (VFs). With the value set to false the SR-IOV Network Operator manages and configures all VFs on the PF.
|
When externallyManaged is set to true , you must manually create the Virtual Functions (VFs) on the physical function (PF) before applying the SriovNetworkNodePolicy resource. If the VFs are not pre-created, the SR-IOV Network Operator’s webhook will block the policy request.
When externallyManaged is set to false , the SR-IOV Network Operator automatically creates and manages the VFs, including resetting them if necessary.
To use VFs on the host system, you must create them through NMState, and set externallyManaged to true . In this mode, the SR-IOV Network Operator does not modify the PF or the manually managed VFs, except for those explicitly defined in the nicSelector field of your policy. However, the SR-IOV Network Operator continues to manage VFs that are used as pod secondary interfaces.
|
|
10 |
The NIC selector identifies the device to which this resource applies. You do not have to specify values for all the parameters. It is recommended to identify the network device with enough precision to avoid selecting a device unintentionally.
If you specify rootDevices , you must also specify a value for vendor , deviceID , or pfNames . If you specify both pfNames and rootDevices at the same time, ensure that they refer to the same device. If you specify a value for netFilter , then you do not need to specify any other parameter because a network ID is unique.
|
11 |
Optional: The vendor hexadecimal vendor identifier of the SR-IOV network device. The only allowed values are 8086 (Intel) and 15b3 (Mellanox). |
12 |
Optional: The device hexadecimal device identifier of the SR-IOV network device. For example, 101b is the device ID for a Mellanox ConnectX-6 device. |
13 |
Optional: An array of one or more physical function (PF) names the resource must apply to. |
14 |
Optional: An array of one or more PCI bus addresses the resource must apply to. For example 0000:02:00.1 . |
15 |
Optional: The platform-specific network filter. The only supported platform is Red Hat OpenStack Platform (RHOSP). Acceptable values use the following format: openstack/NetworkID:xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx . Replace xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx with the value from the /var/config/openstack/latest/network_data.json metadata file. This filter ensures that VFs are associated with a specific OpenStack network. The operator uses this filter to map the VFs to the appropriate network based on metadata provided by the OpenStack platform. |
16 |
Optional: The driver to configure for the VFs created from this resource. The only allowed values are netdevice and vfio-pci . The default value is netdevice .
For a Mellanox NIC to work in DPDK mode on bare metal nodes, use the netdevice driver type and set isRdma to true .
|
17 |
Optional: Configures whether to enable remote direct memory access (RDMA) mode. The default value is false .
If the isRdma parameter is set to true , you can continue to use the RDMA-enabled VF as a normal network device. A device can be used in either mode.
Set isRdma to true and additionally set needVhostNet to true to configure a Mellanox NIC for use with Fast Datapath DPDK applications.
|
You cannot set the isRdma parameter to true for intel NICs.
|
|
18 |
Optional: The link type for the VFs. The default value is eth for Ethernet. Change this value to 'ib' for InfiniBand.
When linkType is set to ib , isRdma is automatically set to true by the SR-IOV Network Operator webhook. When linkType is set to ib , deviceType should not be set to vfio-pci .
Do not set linkType to eth for SriovNetworkNodePolicy, because this can lead to an incorrect number of available devices reported by the device plugin.
|
19 |
Optional: To enable hardware offloading, you must set the eSwitchMode field to "switchdev" . For more information about hardware offloading, see "Configuring hardware offloading". |
20 |
Optional: To exclude advertising an SR-IOV network resource’s NUMA node to the Topology Manager, set the value to true . The default value is false . |